Compaq AA-RHGWC-TE manual Cabling the TZ88N-VA, TZ88N-VA Switch Settings

Models: AA-RHGWC-TE

1 362
Download 362 pages 28.43 Kb
Page 217
Image 217

Table 8–1: TZ88N-VA Switch Settings

SCSI ID

SCSI ID Selection Switches

 

 

 

 

1

2

3

4

5

6

 

 

 

 

 

 

 

Automatica

Off

Off

Off

On

On

On

0

Off

Off

Off

Off

Off

Off

 

 

 

 

 

 

 

1

On

Off

Off

Off

Off

Off

 

 

 

 

 

 

 

2

Off

On

Off

Off

Off

Off

 

 

 

 

 

 

 

3

On

On

Off

Off

Off

Off

 

 

 

 

 

 

 

4

Off

Off

On

Off

Off

Off

 

 

 

 

 

 

 

5

On

Off

On

Off

Off

Off

 

 

 

 

 

 

 

6

Off

On

On

Off

Off

Off

 

 

 

 

 

 

 

7

On

On

On

Off

Off

Off

aSBB tape drive SCSI ID is determined by the SBB physical slot.

8.1.2Cabling the TZ88N-VA

There are no special cabling restrictions specific to the TZ88N-VA; it is installed in a BA350 StorageWorks enclosure. A DWZZA-VA installed in slot 0 of the BA350 provides the connection to the shared SCSI bus. The tape drive takes up three slots.

You must remove the DWZZA-VA differential terminators. Ensure that DWZZA-VA jumper J2 is installed to enable the single-ended termination. The BA350 jumper and terminator must be installed.

A trilink connector on the DWZZA-VA differential end allows connection to the shared bus. An H879-AA terminator is installed on the trilink for the BA350 on the end of the bus to provide shared SCSI bus termination.

Configuring a Shared SCSI Bus for Tape Drive Use 8–3

Page 217
Image 217
Compaq AA-RHGWC-TE manual Cabling the TZ88N-VA, TZ88N-VA Switch Settings