Table34: Hardware Components Used in Configuration Shown in Figure35 Through Figure 38
Callout Number Description

1BN38C cablea

2BN37A cableb
3H8861-AA VHDCI trilink connector

4H8863-AA VHDCI terminatorb

aThemaximum length of theBN38C (or BN38D) cable on one SCSI bus segment must not exceed 25 meters.
bThemaximum combined length of the BN37A cables must not exceed 25 meters.
Figure 36 shows a two-member TruCluster Server configuration with aradially connected dual-redundant HSZ80 RAID array controller configuredfor transparent failover.Figure 36: Shared SCSI Bus with HSZ80 Configured for TransparentFailover
KZPBA-CB (ID 7)
Network
Memory
Channel
Interface Memory Channel
KZPBA-CB (ID 6)
Memory Channel

Member

System

2

Member

System

1

StorageWorks
RAID Array 8000
HSZ80
HSZ80
Controller A Controller B
DS-DWZZH-03
T
TT
T
23
1
4
1
3
Port 1 Port 2
2
Port 1 Port 2
T
T
ZK-1600U-AI
Table34 shows the components used to create the cluster shown in
Figure 36.

Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 321