7.4Determining AlphaServer GS80/160/320 System Configuration
You may be required to reconfigure an AlphaServer GS80/160/320 system that is not familiar to you. Before you start to reconfigure any system, you need to determine:
•The number of partitions in the system
•Which QBBs are in each partition
•Which PCI drawers are used by each partition
•Which PCI drawer is connected to each QBB
•The console serial bus (CSB) addresses
Determine the necessary information with the following system control manager (SCM) commands: show nvr (Example
If you are at the SRM prompt, use the escape sequence (Esc Esc scm) to transfer control to the SCM firmware.
Example
Example 7–3: Displaying AlphaServer GS160 System Information
SCM_E0> show system
System Primary QBB0 : 2
System Primary CPU : 0 on QBB2
1 | 2 | 3 | 4 | 5 |
Par hrd/sft | CPU | Mem | IOR3 IOR2 IOR1 IOR0 | |
| QBB# | 3210 | 3210 | (pci_box.rio) |
6 | 7 | 8 | 9 |
| 10 |
|
GP | QBB | Dir PS | Temp | |||
Mod | BP | Mod 321 (ºC) |
(0) | 0/30 | PPPP | .- P0.1 | P0.0 | P | P | P | 27.0 | ||||
(0) | 1/31 | PPPP | .- | P | P | P | 26.0 | |||||
(1) | 2/32 | PPPP | .- P1.1 | P1.0 | P | P | P | PP- | 26.0 | |||
(1) | 3/33 | PPPP | .- | P | P | P | PP- | 27.0 | ||||
HSwitch | Type | Cables 7 6 5 4 | 3 2 1 | 0 | Temp(ºC) |
|
|
|
HPM40 | - - - - P P P P | 29.0 |
11
12 |
|
|
|
|
|
|
| 13 |
|
|
|
|
|
|
|
| 14 |
| 15 | |
PCI | RIO | PS | ||||||||||||||||||
Cab 7 | 6 | 5 | 4 | 3 | 2 | 1 |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 1 | 0 | 21 | |||
10 | L L L M | - M - | M L L L | L L S | * * PP | |||||||||||||||
11 | L L L M | - M - | M L L L | L L S | * * PP |
16
Temp (ºC)
30.5
30.0
1
Hard partition number. There are two hard partitions in this example (0 and 1).