Figure 9–13: Externally Terminated Shared SCSI Bus with HSZ50 RAID Array Controllers at Bus End

Network

Member

System

1

Memory Channel

KZPSA-BB (ID 6)

Memory

Channel

Interface

Member

System

2

Memory Channel

KZPSA-BB (ID 7)

T

 

3

 

 

 

 

 

 

 

1

1

4

3

4

3

2

 

2

T

 

 

 

 

HSZ50

Controller A

HSZ50

Controller B

ZK-1597U-AI

Table 9–3 shows the components used to create the cluster shown in Figure 9–12 and Figure 9–13.

Table 9–3: Hardware Components Used for Configuration Shown in Figure 8–12 and Figure 8–13

Callout Number

Description

1

BN21W-0B Y cable

 

 

2

H879-AA terminator

 

 

3

BN21K (or BN21L) cablea b

4

H885-AA trilink connector

aThe maximum combined length of the BN21K (or BN21L) cables must not exceed 25 meters.

bThe cable between the H885-AA trilink connectors on the HSZ50s could be a BN21L-0B, a 0.15-meter cable.

Configurations Using External Termination or Radial Connections to Non-UltraSCSI Devices 9–27

Page 319
Image 319
Compaq AA-RHGWC-TE manual BN21K or BN21L cablea b