Figure 913: Externally Terminated Shared SCSI Bus with HSZ50 RAIDArray Controllers at Bus End
KZPSA-BB (ID 7)
Network
Memory
Channel
Interface
Memory Channel
KZPSA-BB (ID 6)
Memory Channel
Member
System
2
Member
System
1
211
2T
T3
433
4
HSZ50
Controller A Controller B
HSZ50
ZK-1597U-AI
Table93 shows the components used to create the cluster shown inFigure 912 and Figure 913.Table93: HardwareComponents Used for Configuration Shown in Figure812 and Figure 813
Callout Number Description

1BN21W-0B Y cable

2H879-AA terminator

3BN21K (or BN21L) cableab

4H885-AA trilink connector

aThemaximum combined length of the BN21K (or BN21L) cables must not exceed 25 meters.
bThecable between the H885-AA trilink connectors on the HSZ50s couldbea BN21L-0B, a 0.15-meter cable.
Configurations Using External Termination or Radial Connections to

Non-UltraSCSI Devices 927