
There are two console level Memory Channel diagnostics, mc_diag and mc_cable:
•The mc_diag diagnostic:
–Tests the Memory Channel adapter(s) on the system running the diagnostic.
–Runs as part of the initialization sequence when the system is powered up.
–Runs on a standalone system or while connected to another system or a hub with the link cable.
•The mc_cable diagnostic:
–Must be run on all systems in the cluster simultaneously (therefore, all systems must be at the console prompt).
__________________ Caution __________________
If you attempt to run mc_cable on one cluster member while other members of the cluster are up, you may crash the cluster.
–Is designed to isolate problems to the Memory Channel adapter, BC12N or BN39B link cables, hub linecards, fiber optics converters, BN34R fiber optics cable, and, to some extent, to the hub.
–Indicates data flow through the Memory Channel by response messages.
–Runs continuously until terminated with Ctrl/C.
–Reports differences in connection state, not errors.
–Can be run in standard or virtual hub mode.
When the console indicates a successful response from all other systems being tested, the data flow through the Memory Channel hardware has been completed and the test may be terminated by pressing Ctrl/C on each system being tested.
Example