6.7.2Procedure to Convert from Transparent to Multiple-bus Failover Mode

To change from transparent failover to multiple-bus failover mode by resetting the unit offsets and modifying the systems’ view of the storage units, follow these steps:

1.Shut down the operating systems on all host systems that are accessing the HSG80 controllers you want to change from transparent failover to multiple-bus failover mode.

2.At the HSG80, set multiple-bus failover as follows. Note that before putting the controllers in multiple-bus failover mode, you must remove any previous failover mode:

HSG80> SET NOFAILOVER

HSG80> SET MULTIBUS_FAILOVER COPY=THIS

____________________ Note _____________________

Use the controller known to have the good configuration information.

3.Execute the SHOW CONNECTION command to determine which connections have a nonzero offset as follows:

HSG80> SHOW CONNECTION

 

 

 

 

 

Connection

 

 

 

 

 

Unit

Name

Operating system

Controller

Port

Address

Status

Offset

!NEWCON49

TRU64_UNIX

THIS

2

230813

OL this

100

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON50

TRU64_UNIX

THIS

1

230813

OL this

0

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON51

TRU64_UNIX

THIS

2

230913

OL this

100

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON52

TRU64_UNIX

THIS

1

230913

OL this

0

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON53

TRU64_UNIX

OTHER

1

230913

OL other

0

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON54

TRU64_UNIX

OTHER

1

230813

OL other

0

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON55

TRU64_UNIX

OTHER

2

230913

OL other

100

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON56

TRU64_UNIX

OTHER

2

230813

OL other

100

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON57

TRU64_UNIX

THIS

2

 

offline

100

Using Fibre Channel Storage 6–59