Table 10–3: Installing a KZPSA-BB or KZPBA-CB for Use with External Termination

Step

Action

Refer to:

1

Remove the KZPSA-BB internal termination

Section 10.1.4.4,

 

resistors, Z1, Z2, Z3, Z4, and Z5.

Figure 10–1, and KZPSA

 

 

PCI-to-SCSI Storage

 

 

Adapter Installation

 

 

and User’s Guide

2

3

Remove the eight KZPBA-CB internal termination

Section 4.3.3.3,

resistor SIPs, RM1-RM8.

Figure 4–1, and

 

KZPBA-CB PCI-to-Ultra

 

SCSI Differential Host

 

Adapter User’s Guide

Power down the member system. Install

KZPSA PCI-to-SCSI

a KZPSA-BB PCI-to-SCSI bus adapter or

Storage Adapter

KZPBA-CB UltraSCSI host adapter in the PCI

Installation and User’s

slot corresponding to the logical bus to be used for

Guide and KZPBA-CB

the shared SCSI bus. Ensure that the number

PCI-to-Ultra SCSI

of adapters are within limits for the system,

Differential Host Adapter

and that the placement is acceptable.

User’s Guide

Install a BN21W-0B Y cable on each KZPSA-BB

or KZPBA-CB host adapter.

 

4

Install an H879-AA terminator on one leg of the

 

BN21W-0B Y cable of the member system that

 

 

will be on the end of the shared SCSI bus.

 

 

 

 

5

Power up the system, and update the system

Firmware release

 

SRM console firmware and KZPSA-BB host

notes for the system

 

bus adapter firmware from the latest Alpha

(Section 4.2) and

 

Systems Firmware Update CD-ROM.

Section 10.1.4.5

______________________ Note ______________________

The SRM console firmware includes the ISP1020/1040-based PCI option firmware, which includes the KZPBA-CB. When you update the SRM console firmware, you are enabling the KZPBA-CB firmware to be updated. On a powerup reset, the SRM console loads KZPBA-CB adapter firmware from the console system flash ROM into NVRAM for all Qlogic ISP1020/1040-based PCI options, including the KZPBA-CB PCI-to-Ultra SCSI adapter.

6Use the show config and show device console commands to display the installed devices

and information about the KZPSA-BBs or KZPBA-CBs on the AlphaServer systems. Look for KZPSA or pk* in the display to determine which devices are KZPSA-BBs. Look for QLogic ISP1020 in the show config display and isp in the show device display to determine which devices are KZPBA-CBs.

Section 10.1.3 and Example 10–1 through Example 10–4

Configuring Systems for External Termination or Radial Connections to Non-UltraSCSI Devices 10–7

Page 331
Image 331
Compaq AA-RHGWC-TE manual Power down the member system. Install