current_temp

Signed 8-bit value containing the current temperature of the board within the range -128 to 127 degrees Celsius.

max_temp

Signed 8-bit value containing the maximum temperature the board has reached since SSDM was last started. Value is within the range -128 to 127 degrees Celsius.

6.2.4MGT_MSG_CONFIG0 – Board Configuration Request

Synopsis

Message sent to a board immediately after starting the code running to provide physical configuration parameters.

Note: When using the s7_mgt protocol configuration utility, this message is generated by s7_mgt and should not be generated by the user.

Format

 

 

 

MESSAGE HEADER

 

 

 

 

 

Field Name

Meaning

 

 

 

 

type

 

 

MGT_MSG_CONFIG0 (0x7f10)

 

 

 

 

id

 

 

0

 

 

 

 

src

 

 

Sending module ID

 

 

 

 

dst

 

 

MGMT_module_ID

 

 

 

 

rsp_req

 

 

Used to request a confirmation.

 

 

 

 

hclass

 

 

0

 

 

 

 

status

 

 

0

 

 

 

 

err_info

 

 

0

 

 

 

 

len

 

 

68

 

 

 

 

 

 

 

PARAMETER AREA

 

 

 

 

Offset

 

Size

Name

 

 

 

 

0

 

2

config_type

 

 

 

 

2

 

2

flags

 

 

 

 

4

 

2

l1_flags

 

 

 

 

6

 

62

Reserved. Must be set to 0.

 

 

 

 

Description

This message must be the first message sent to the board once the SS7 software is running. It is used to configure layer1 modules on the board for operation. The message contains flags to permit various level 1 configurations. The physical link parameters are configured on a per link basis using the MGT_MSG_L1_CONFIG command.

The confirmation message (if requested) indicates success with a status value of 0. To ensure that configuration is complete before subsequent messages are issued to the board, the user should always request a confirmation message and check the status for success.

If the board is not licensed to run the requested software configuration, a status value of 0xfe is returned.

Parameters

The MGT_MSG_CONFIG0 message includes the following parameters:

config_type

Set to 3 when using a DSI SS7MD Board. A separate link layer configuration message should be sent for each link using the MGT_MSG_L1_CONFIG message.

flags

Global flags with the following bit significance: