7 Configuration Command Reference

7.1.5STREAM_XCON – Cross Connect Configuration

Synopsis

The STREAM_XCON command controls the cross connect switch on the signaling boards, enabling the cross- connection of timeslots between two Line Interface Unit (LIU) on each signaling board. The LIUs on a board are referenced by a fixed logical stream number.

Note: The <mode> option 1 and <pattern> parameter is not supported on DSI SS7MD Boards.

Syntax

STREAM_XCON <bpos> <stream_a> <stream_b> <mode> <ts_mask> <pattern>

Example

STREAM_XCON 3 2 3 3 0xfffefffe 0

Parameters

The STREAM_XCON command includes the following parameters:

<bpos>

The board position of the cross connect switch to be controlled. There must be a valid board at this position (previously defined by an SS7_BOARD command).

<stream_a>

A reference to the 2 Mb/s stream for the output of the connection. There must be a valid LIU at this position (previously defined by a LIU_CONFIG command). Valid values are:

Board Type

Stream

E1/T1/J1

Interface

 

 

 

 

 

SPCI4,

0

L1

SS7HDP,

 

 

1

L2

 

SS7HDE,

 

 

2

L3

SS7MDL4

 

 

 

3

L4

 

 

 

 

2

L3

SPCI2S

 

 

3

L4

 

 

 

 

<stream_b>

A reference to the 2 Mb/s stream for the input of a simplex connection (mode 2) or one half of a duplex cross connection (mode 3). In other modes, this field should be set to 0. There must be a valid LIU at this position (previously defined by a LIU_CONFIG command). For valid values, see the table in the <stream_a> parameter description above.

<mode>

Indicates the requested cross connect switch function according to the following table.

Mode

Function

1Not supported

2Connect the input timeslot to the output timeslot

3Duplex cross-connect the input and output timeslot

<ts_mask>

A 32-bit mask specifying the timeslots to apply the cross connect to. Each bit corresponds to a timeslot in the input/output stream. Bit 0 (the least significant bit) corresponds to timeslot number 0. To apply this command to a timeslot, the corresponding bit must be set to one.

124

Page 124
Image 124
Dialogic DSI SS7MD manual Board Type Stream E1/T1/J1 Interface, Mode Function