Dialogic® DSI SS7MD Programmer’s Manual Issue 3
Description
QSAAL_MSG_CFG_LINK messages may be issued to the Q.SAAL module to modify timer configuration parameters. Otherwise default timer values will be used.
Timer ID | Default Value (ms) |
| Range (min - max) |
|
|
|
|
Timer CC | 1500 | 15 | - 2,500 |
|
|
|
|
Time_keep_alive | 300 | 15 | - 2,500 |
|
|
| |
Timer_no_resp | 1500 | 100 - 10,000 | |
|
|
|
|
Timer_poll | 100 | 20 | - 600 |
|
|
|
|
Timer_idle | 100 | 20 | - 600 |
|
|
| |
Timer T1 | 5000 | 1,000 - 20,000 | |
|
|
| |
Timer T2 | 120000 | 10,000 - 300,000 | |
|
|
| |
Timer T3 | 10 | 1 - 30 | |
|
|
|
|
•Timer_CC
Time between transmission of
•Timer_keep_alive
Time between keep alive messages.
•Timer_no_resp
Time interval during which a STAT PDU must be received, otherwise the link has failed
•Timer_poll
Poll timer interval
•Timer_idle
Maximum Idle phase time of an SSCOP connection
•Timer_T1
Time between link release and link
•Timer_T2
Maximum time to attempt link alignment.
•Timer_T3
Time between proving PDUs.
Note: The timers are specified in milliseconds.
93