Dialogic® DSI SS7MD Programmer’s Manual Issue 3

6.3.1 LIU_MSG_CONFIG – LIU Configuration Request

Synopsis

Message sent by the application to establish the operating mode for a Line Interface Unit (LIU).

Note: When using the s7_mgt protocol configuration utility, this message is generated by s7_mgt as a result of the LIU_CONFIG command. It therefore need not be generated by the user.

Format

 

 

 

MESSAGE HEADER

 

 

 

 

 

Field Name

Meaning

 

 

 

 

type

 

 

LIU_MSG_CONFIG (0x7e34)

 

 

 

 

id

 

 

liu_id (in the range 0 to one less than the number of LIUs)

 

 

 

 

src

 

 

Sending module ID

 

 

 

 

dst

 

 

MVD_module_ID

 

 

 

 

rsp_req

 

 

Used to request a confirmation.

 

 

 

 

hclass

 

 

0

 

 

 

 

status

 

 

0

 

 

 

 

err_info

 

 

0

 

 

 

 

len

 

 

40

 

 

 

 

 

 

 

PARAMETER AREA

 

 

 

 

Offset

 

Size

Name

 

 

 

 

0

 

1

liu_type

 

 

 

 

1

 

1

liu_code

 

 

 

 

2

 

1

frame_format

 

 

 

 

3

 

1

crc_mode

 

 

 

 

4

 

1

build_out

 

 

 

 

5

 

6

Reserved. Must be set to 0.

 

 

 

 

11

 

1

ais_gen

 

 

 

 

12

 

6

Reserved. Must be set to 0.

 

 

 

 

18

 

1

high_Z

 

 

 

 

19

 

2

clk_options

 

 

 

 

21

 

19

Reserved. Must be set to 0.

 

 

 

 

Description

This message is sent to the board to configure the operating mode of a Line Interface Unit (LIU). All configuration parameters must be supplied in the message, that is, it is not possible to modify individual operating parameters in isolation. On receipt of the message, the board first verifies that the fitted hardware options support the requested operating mode and then initializes (or reinitializes) the LIU.

The confirmation message (if requested) indicates success with a status value of 0.

Parameters

A description of the permitted parameter values are given below. When the board is initially configured, the LIUs are initialized to a disabled condition. The LIU_MSG_CONFIG message includes the following parameters:

liu_type

The physical interface type according to the following table. The preferred method for configuring an E1 interface is to set a value of 5.

Value

Description

 

 

1

Disabled (used to deactivate a LIU). In this mode, the LIU does not produce an

output signal.

 

 

 

59

Page 59
Image 59
Dialogic DSI SS7MD manual Liumsgconfig LIU Configuration Request, Field Name Meaning