Dialogic® DSI SS7MD Programmer’s Manual Issue 3

7.5.3ISUP_TIMER – Configure ISUP Timers

Synopsis

The ISUP_TIMER command provides the ability to configure the ISUP protocol timers from the config.txt file.

Syntax

ISUP_TIMER <reserved> <timer_id> <value>

Example

ISUP_TIMER 0 t4 550

Parameters

The ISUP_TIMER command includes the following parameters:

<reserved>

Must be set to 0. Reserved for future use.

<timer_id>

The text identifier for the timer to be configured. The supported set of timer mnemonics is shown in the table below.

<value>

The timer value in seconds, except T29 and T30 that are in multiples of tenths of a second (100 ms). Any timers not explicitly set are set to their default values, as shown in the table below.

Timer

Default Value

Timer

Default Value

Timer

Default Value

Mnemonic

(Seconds)

Mnemonic

(Seconds)

Mnemonic

(Seconds)

 

 

 

 

 

 

T1

10

T15

60

T28

10

 

 

 

 

 

 

T2

180

T16

10

T29

0.5

 

 

 

 

 

 

T3

180

T17

60

T30

8

 

 

 

 

 

 

T4

300

T18

10

T33

14

 

 

 

 

 

 

T5

60

T19

60

T34

3

 

 

 

 

 

 

T6

180

T20

10

T35

20

 

 

 

 

 

 

T7

25

T21

60

T36

13

 

 

 

 

 

 

T8

13

T22

10

T38

150

 

 

 

 

 

 

T9

45

T23

60

T39

10

 

 

 

 

 

 

T10

5

T24

2

T103

20

 

 

 

 

 

 

T12

10

T25

5

T104

3

 

 

 

 

 

 

T13

60

T26

120

 

 

 

 

 

 

 

 

T14

10

T27

240

 

 

 

 

 

 

 

 

143

Page 143
Image 143
Dialogic DSI SS7MD manual Timer Default Value Mnemonic Seconds