6 Message Reference
6.3.4LIU_MSG_R_CONTROL – LIU Read Control Request
Synopsis
Message sent by the application to read back the current Line Interface Unit (LIU) control options from the board.
Format
|
|
| MESSAGE HEADER |
|
|
|
|
| Field Name | Meaning | |
|
|
|
|
type |
|
| LIU_MSG_R_CONTROL (0x5e38) |
|
|
|
|
id |
|
| liu_id (in the range 0 to one less than the number of LIUs) |
|
|
|
|
src |
|
| Sending module ID |
|
|
|
|
dst |
|
| MVD_module_ID |
|
|
|
|
rsp_req |
|
| Used to request a confirmation. |
|
|
|
|
hclass |
|
| 0 |
|
|
|
|
status |
|
| 0 |
|
|
|
|
err_info |
|
| 0 |
|
|
|
|
len |
|
| 16 |
|
|
|
|
|
|
| PARAMETER AREA |
|
|
|
|
Offset |
| Size | Name |
|
|
|
|
|
|
| Parameter area formatted in the same manner as the |
|
|
| LIU_MSG_CONTROL message. |
0 |
| 16 | All fields should be set to 0. The confirmation message contains LIU |
| control options. | ||
|
|
| |
|
|
| The user should set the fields to 0 and the module writes the current |
|
|
| control parameters in the confirmation message. |
|
|
|
|
Description
This message is sent to the board to read back the current control parameters selected for a Line Interface Unit (LIU). The user should always request a confirmation message. The confirmation message indicates success when the status value of 0 and contains the current control parameters in the parameter area of the message.
6.3.5MVD_MSG_RESETSWX – Reset Switch Request
Synopsis
Resets the digital switch to its default state in accordance with the current board configuration.
Format
| MESSAGE HEADER |
|
|
Field Name | Meaning |
|
|
type | MVD_MSG_RESETSWX (0x7e00) |
|
|
id | 0 |
|
|
src | Sending module ID |
|
|
dst | MVD_module_ID |
|
|
rsp_req | Used to request a confirmation. |
|
|
hclass | 0 |
|
|
status | 0 |
|
|
err_info | 0 |
|
|
len | 0 |
|
|
Description
This message is sent to the board to reset the state of the digital cross connect switch.
64