Dialogic® DSI SS7MD Programmer’s Manual Issue 3

7.1.4SCBUS_LISTEN – Connect Switch Timeslot to LIU Timeslot

Synopsis

This command establishes a connection from the switch to an outgoing timeslot on the Line Interface Unit (LIU).

Note: Dynamic modification of voice paths can only be performed by issuing messages directly to the board. The MVD_MSG_SC_LISTEN message is recommended for this purpose.

Syntax

SCBUS_LISTEN <board_id> <liu_id> <timeslot> <sc_channel>

Example

SCBUS_LISTEN 0 0 31 23

Parameters

The SCBUS_LISTEN command includes the following parameters:

<board_id>

The logical identity of the board in the range from 0 to one less than the number of boards supported.

<liu_id>

The identifier of the T1/E1/J1 Line Interface Unit (LIU) in the range 0 to one less than the number of LIUs.

<timeslot>

The timeslot number on the T1/E1/J1 LIU on which the data from the switch will be transmitted. The valid ranges are:

For a T1 interface: 1 to 24.

For an E1 interface: 1 to 31.

For a J1 interface: 1 to 24.

<sc_channel>

The channel number on the switch to which the LIU will listen. This should be in the range from 0 to one less than the total number of channels on the switch.

123

Page 123
Image 123
Dialogic DSI SS7MD manual Scbuslisten boardid liuid timeslot scchannel