Dialogic® DSI SS7MD Programmer’s Manual Issue 3

10T1 long haul LB0 (-15dB)

11Not supported.

12T1 long haul LBO (-22.5dB)

ais_gen

The (initial) mode used to generate the Alarm Indication Signal (Blue alarm). The user may subsequently modify the setting of the outgoing signal using the LIU_MSG_CONTROL message. The following table shows the permitted values and their meanings.

Value

Description

1Disabled; do not generate AIS/Blue alarm

2Enabled; generate AIS/Blue alarm

high_Z

The mode settings to allow interface high impedance for monitoring purposes. The following table shows the permitted values and their meanings.

Value

Description

1Disabled; normal impedance presented on the line

2Enabled; set the LIU to high impedance for monitoring

clk_options

A 16-bit value containing clocking options for the LIU. This value provides the ability to override default LIU clocking options for each LIU. Default options are specified per board within the MGT_MSG_CONFIG0 message.

Bit 0 - Disable LIU clock recovery for this interface.

All other bits set to 0.