Dialogic® DSI SS7MD Programmer’s Manual Issue 3
messages may be issued to the MTP2 module to modify timer configuration parameters however; these messages do not affect SS7 operation (that is, the power up sequence is not
For backwards compatibility, the MTP2 module accepts messages with three different parameter area lengths: 38, 42 or 60 bytes. If the length is less than 42, the cong_discard parameter is set to 0 so that congestion discard does not take place, and the l3_link_id parameter is set to the same value as the l2_llid. If the length is less than 60, then the use of single congestion thresholds is assumed.
Note: To use multiple congestion thresholds, it is necessary to set the S7C_MCONG bit (bit 3) in the options field in addition to supplying a full length parameter area.
•options
This field is used to convey
Bit | Meaning | |
|
| |
0 | Set to 1 to enable the Preventive Cyclic Retransmission of error correction or set to 0 to | |
enable the Basic Method of error correction. | ||
| ||
|
| |
2 | Set to 1 to enable ANSI operation or set to 0 to enable ITU operation. | |
|
| |
3 | Set to 1 to enable the Multiple Congestion States and Multiple Message Priority option. | |
This option should always be enabled when running in ANSI mode. | ||
| ||
|
| |
7 | Set to 1 to invoke special MTP2 operation for use in Japanese networks. | |
|
| |
9 | Set to 1 to cause the link to operate in receive only mode for use in monitoring | |
applications. | ||
| ||
|
| |
11 | Set to 1 for HSL operation. Must be set to 0 for conventional SS7 operation. | |
|
| |
12 | Set to 1 for | |
|
| |
Others | Reserved for future use. Must be set to 0. | |
|
|
•upper_id
The module ID of the upper layer module. This is the module to which all MTP2/MTP3 indications are to be issued and is typically the module ID of the MTP3 module.
•lower_id
The module ID of the onboard driver module that interfaces with the physical interface. This must be set to 0.
•mgmt_id
The module ID of the management module to which all trace messages, event indications and state change messages are to be sent.
•max_SIF_len
The maximum length of signaling Information Field (SIF) to support. This should be set to either 62 or 272 in accordance with Q.703.
•cong_onset
The congestion onset threshold for use with the single congestion threshold mode of operation. Congestion is indicated when the total number of messages in the transmit and retransmit buffers rises to this value.
•cong_abate
The congestion abatement threshold for use with the single congestion threshold mode of operation. Link uncongested is indicated when the total number of messages in the transmit and retransmit buffers falls below this value.
•pcr_n1
The N1 threshold for use with the Preventive Cyclic Retransmission method of error correction. For
•pcr_n2
The N2 threshold for use with the Preventive Cyclic Retransmission method of error correction. This should typically be set to approximately 8 times the loop delay in ms for 64 kbits/s operation or 7 times