Dialogic® DSI SS7MD Programmer’s Manual Issue 3

The confirmation message (if requested) indicates success with a status value of 0. On receipt of the confirmation message, the operation to reset the switch is completed.

6.3.6MVD_MSG_SC_CONNECT – Connect Request

Synopsis

Message sent to the board to control the switch path.

Format

 

 

 

MESSAGE HEADER

 

 

 

 

Field Name

 

Meaning

 

 

 

 

type

 

MVD_MSG_SC_CONNECT (0x7e1f)

 

 

 

 

id

 

0

 

 

 

 

src

 

Sending module ID

 

 

 

 

dst

 

MVD_module_ID

 

 

 

 

rsp_req

 

Used to request a confirmation.

 

 

 

 

hclass

 

0

 

 

 

 

status

 

0

 

 

 

 

err_info

 

0

 

 

 

 

len

 

16

 

 

 

 

 

 

 

PARAMETER AREA

 

 

 

 

Offset

 

Size

Name

 

 

 

 

0

 

2

local_stream

 

 

 

 

2

 

2

local_slot

 

 

 

 

4

 

2

mode

 

 

 

 

6

 

2

source_stream

 

 

 

 

8

 

2

source_slot

 

 

 

 

10

 

2

dest_stream

 

 

 

 

12

 

2

dest_slot

 

 

 

 

14

 

2

Reserved. Must be set to 0.

 

 

 

 

Description

This message is sent to the board to control the cross connect switch. Several different actions can be performed depending on the value of the mode parameter. These include:

Cross connect switch to CPU local bus stream connection

Local bus to cross connect switch connection

Duplex connection between cross connect switch and CPU local bus stream

Duplex connection between local bus timeslots

Attempting to use this message in a run mode where the cross connect switch is disabled will result in a failure return code.

The confirmation message (if requested) indicates success with a status value of 0.

65

Page 65
Image 65
Dialogic DSI SS7MD manual Localstream