Dialogic® DSI SS7MD Programmer’s Manual Issue 3
—Bit 12 is used to select 12- or
—Bits 13 and 14 reserved. Set to 0.
—Bit 15 is set to 1 to disable the link. This bit should be set to 0 to enable normal link operation.
—All other bits are reserved for future use and should be set to 0.
•<data_rate>
An optional parameter to specify link parameters, required for HSL or ATM operation. The valid values are:
Value | Description | |
|
| |
TDM | single timeslot SS7 LSL (default) | |
|
| |
E1_FRAMED | HSL structured 31 slot E1 operation | |
|
| |
T1_FRAMED | HSL structured 24 slot T1/J1 operation | |
|
| |
E1_PCM | HSL structured 30 slot E1 operation (where | |
timeslots 0 and 16 are not used for signaling) | ||
| ||
|
| |
ATM | The command follows the syntax for ATM links | |
|
|
MTP HSL/LSL Link Parameters
•
•
•
<board_id>
The logical identity of the board in the range 0 to one less than the number of boards supported.
<blink>
The index of the signaling link. It must be in the range 0 to one less than the number of signaling links licensed on the board.
<stream>
When the <timeslot> parameter is set to a
identity of the T1/E1/J1 LIU (liu_id) containing the signaling link. It should be in the range 0 to one less than the number of LIUs.
•<timeslot>
The timeslot used for signaling in the range 0 to 31. The valid ranges are:
—For a T1 interface: 1 to 24.
—For an E1 interface: 1 to 31.
—For a J1 interface: 1 to 24.
For HSL operation:
—0xff - Data rate is set using the optional data rate parameter, if not present data rate defaults based on LIU type (T1/E1).
—All other values are reserved for future use.
ATM Link Parameters
•<board_id>
The logical identity of the board in the range from 0 to one less than the number of boards supported. This should be the same value as used in the ATM_STREAM command. If the value selected is different, then the configuration will be rejected.
•<blink>
The index of the signaling link. It must be in the range 0 to one less than the number of signaling links licensed on the board.
•<atm_stream>
This defines the logical id of the cell stream over which the link runs. It must be in the range 0 to one less than the combined number of ATM Cell Streams supported by all the SS7MD boards in the system.
•
This is a compound parameter that identifies the VPI and VCI of the ATM link. It is represented in the form