6 Message Reference

6.3.2LIU_MSG_CONTROL – LIU Control Request

Synopsis

Message sent by the application to dynamically control operation for a Line Interface Unit (LIU). Allows setting of outgoing alarms and diagnostic loopbacks.

Format

 

 

 

MESSAGE HEADER

 

 

 

 

 

Field Name

Meaning

 

 

 

 

type

 

 

LIU_MSG_CONTROL (0x7e35)

 

 

 

 

id

 

 

liu_id (in the range 0 to one less than the number of LIUs)

 

 

 

 

src

 

 

Sending module ID

 

 

 

 

dst

 

 

MVD_module_ID

 

 

 

 

rsp_req

 

 

Used to request a confirmation.

 

 

 

 

hclass

 

 

0

 

 

 

 

status

 

 

0

 

 

 

 

err_info

 

 

0

 

 

 

 

len

 

 

16

 

 

 

 

 

 

 

PARAMETER AREA

 

 

 

 

Offset

 

Size

Name

 

 

 

 

0

 

1

ais_gen

 

 

 

 

1

 

1

Reserved for future use, must be set to 0.

 

 

 

 

2

 

1

loop_mode

 

 

 

 

3

 

1

Reserved for future use, must be set to 0.

 

 

 

 

4

 

1

prbs_gen

 

 

 

 

5

 

11

Reserved for future use, must be set to 0.

 

 

 

 

Description

This message is sent to the board to perform dynamic changes to the operation of the Line Interface Unit (LIU). It allows the user to control the generation of AIS (Blue alarm) and to activate various diagnostic loopback modes. It also allows the configuration of PRBS test sequences.

The confirmation message (if requested) indicates success with a status value of 0.

Parameters

The LIU_MSG_CONTROL message includes the following parameters:

ais_gen

The mode used to generate the Alarm Indication Signal (Blue alarm). The following table shows the permitted values and their meanings.

Value

Description

0Do not change AIS/Blue alarm generation mode

1Disabled; do not generate AIS/Blue alarm

2Enabled; generate AIS/Blue alarm

62

Page 62
Image 62
Dialogic DSI SS7MD manual Reserved for future use, must be set to