Fluke 435 user manual 20-12

Models: 435

1 140
Download 140 pages 63.82 Kb
Page 106
Image 106

Fluke 434/435

Users Manual

2

3

Phase Colors: use the function keys F1 ... F4 to choose colors as used in the USA, EU, UK, or according to IEC. Or define your own set of colors: use the up/down arrow keys to select a phase and use the left/right arrow keys to select a color. Press function key F5 – OK to confirm.

Printer: Use the arrow keys to select and adjust baudrate for use with a printer. Use the up/down arrow keys to select the printer type. Press function key F5 – OK to confirm.

4

5

6

RS-232: Use the left/right arrow keys to adjust communication baudrate (for communication with a PC).

Battery save: Use the up/down arrow keys to select the time after which the Display dims when no keys are operated.

Configuration of Flash Memory: determines the amount of memory available for data logging and screenshots/datasets. Use the up/down arrow keys to select and ENTER to confirm.

7

8

F1 – FACTORY DEFAULTS: resets all settings in this menu to factory default.

F2 – USER ID: access to a menu to define 3 lines with user programmable text (e.g. the owner’s name and address). This text appears in the power-on and SETUP entry screens. Use Function key F3 to insert spaces. Press function key F5 – OK to confirm.

9F3 – CONTRAST: Use left/right arrow keys to adjust the display contrast.

10F4 – CLEAR ALL MEMORY: All datasets, screens, and logging data can be cleared in one action. Protection is achieved via a confirm menu.

11F5 – BACK: return to SETUP entry menu.

20-12