Fluke 434/435
Users Manual
F4
F5
Switch between voltage readout per phase (A/L1,B/L2,C/L3,N) or
Switch between HOLD and RUN of screen update.
Cursor. When the Cursor is on, the waveform values at the Cursor are displayed in the screen header. Positioning the Cursor across the left or right screen end brings the next screen out of a maximum of 6 within viewing area.
Zoom. Allows you to expand or shrink the display vertically and horizontally to view details or to see the complete graph within the screen area. Zoom and Cursor are operated by the arrow keys and are explained in Chapter 19.
The Range of waveforms is preadjusted for a good display in almost all cases. This is based upon Nominal Voltage (Vnom) and Current range (A Range).
If desired, you can change the Range. Also the PHASOR PREFerence is adjustable. This concerns the rotation indication to show phasor rotation or phase sequence and the phase angle representation
Scope Phasor
To access the Phasor screen:
d F3
The Phasor screen displays the phase relation between voltages and currents in a vector diagram. The vector of reference channel A (L1) points in the positive horizontal direction. Additional numerical values are fundamental phase voltage, frequency, and phase angles. The screen header shows rms voltage and/or current values.
Available function keys:
|
|
|
|
| Selection of additional data to be displayed: all voltages, all |
| F1 |
| |||
|
|
|
|
| currents, or voltage and current phase by phase. |
|
|
|
|
|
|
|
|
|
|
| Return to the Scope Waveform. |
| F3 |
| |||
|
|
|
|
|
|
|
|
|
|
| Switch between HOLD and RUN of screen update. |
| F5 |
|
| ||
|
|
|
|
|
|