Limits Adjustments is used to save, recall, and define sets of limits for:

Power Quality Monitoring.

Dips/Interruptions/Rapid Voltage Changes/Swells.

The entry menu is available in the selected information language.

Read below how to do this:

1

Adjust Monitor Limits is the entry menu. It shows the main settings of the active set of limits: name, creation date, and a summary of limits data.

2

Recall Monitor Limits menu is used to recall a set of power quality limits. A maximum of six sets can be recalled:

-Default 1 and 2 are factory installed read-only sets: one of them is the set of limits according to the EN50160 standard.

-Admin 1 and 2 are sets definable by an administrator by means of PC- software: for the user these sets are read-only.

-User 1 and 2 can be defined and saved by the user.

Use the up/down arrow keys to select a set of limits you want to recall. Then press Function key F5 to recall and to use them.

Press Function key F1 to leave the menu without further actions.

3

Edit Monitor Limits menu is used to modify limits. Setups are grouped per power quality item in separate submenus for voltage, harmonics, flicker, etc.

Use the up/down arrow keys to select an item to be adjusted. Then press the ENTER key F5 to enter the adjustment submenu. All adjustment items are listed in the table below.

4

Use the arrow keys to select and edit limits.

Press Function key F5 to confirm selections and return to the Edit Limits menu. Use Function keys F1 – PREVious or F2 – NEXT to move directly to an adjacent submenu. When ready with editing the limits, Press Function key F5 – OK twice to return to the Adjust Monitor Limits menu. Arrow keys can be used here to define a name for the new set of limits. Then press Function key F2 – SAVE to enter the Save Monitor Limits menu.

5

Save Monitor Limits menu is used to save sets of limits in User 1 or 2. Use the up/down arrow keys to select User 1 or User 2. When available save the set of limits in an empty location; saving into a location already filled will overwrite the existing set. Press Function key F5 – SAVE to do the save action. Press F1 – CANCEL to return to the Adjust Monitor Limits menu without saving limits. In this menu you can also define a name for a set of limits to be saved. Use the arrow keys to define a name for a set of limits that you want to save.

6

View Monitor Limits menu. This menu has the same structure as the Edit Monitor Limits menu and can be used to view limits without the risk of changing them.