Fluke 434/435

Users Manual

Harmonics

Measurement Range

Resolution

Accuracy

 

 

 

 

 

Harmonic order (n)

DC, 1..50

Grouping: Harmonic groups according to IEC 61000-4-7

 

 

 

 

 

Inter-Harmonic order

Off, 1..49

Grouping: Harmonic and Interharmonic subgroups according to IEC

 

61000-4-7

 

 

 

 

 

 

 

Filtering

When measuring harmonics with interharmonics off, harmonics group is used

 

and a 1.5 s smoothing filter is active.

 

 

When measuring harmonics with interharmonics on, harmonics subgroup and

 

interharmonics centered subgroup are used and no filter is active.

 

 

 

 

 

Vrms Relative (%f):

0.0

… 100.0%

0.1%

± 0.1% ± n x 0.1%

 

 

 

 

 

(± 0.4% for %r)

Fluke 435 Absolute:

0.0

… 1000 Vrms

0.1 Vrms

± 0.05% of nominal

 

 

 

 

 

voltage if < 1% of

 

 

 

 

 

nominal voltage

 

 

 

 

 

± 5% if ≥ 1% of nominal

 

 

 

 

 

voltage

Fluke 434 Absolute:

0.0

… 1000 Vrms

0.1 Vrms

± 5% ± 2 counts

 

 

 

 

 

Arms Relative (%f):

0.0

… 100.0%

0.1%

± 0.1% ± n x 0.1%

 

 

 

 

 

(± 0.4% for %r)

Absolute:

0.0

… 4000 mV x clamp

1 mVrms x clamp scaling

± 5% ± 5 counts

 

scaling

 

 

 

 

 

 

 

 

Watts Relative:

0.0

… 100.0%

0.1%

± n x 2%

(Harmonics only)

 

 

 

 

 

Watts Absolute:

depends on clamp and

 

± 5% ± n x 2% ± 10

(Harmonics only)

voltage scaling

 

counts

 

 

 

 

 

DC Relative:

0.0

… 100.0%

0.1%

± 0.1% V and A (± 2%

 

 

 

 

 

Watt)

Fluke 435 Absolute V:

0.0

… 1000V

0.1V

± 0.2% of nominal

 

 

 

 

 

voltage

Fluke 434 Absolute V:

0.0

… 1000V

0.1V

± 5% ± 10 counts

Absolute A:

0.0

… 4000 mV x clamp

1 mVrms x clamp scaling

± 5% ± 10 counts

 

scaling

 

0.1V

 

Absolute W:

depends on clamp and

depends on scaling

± 5% ± 10 counts

 

voltage scaling

 

 

 

 

 

 

 

THD(n=40) (relative %f or

0.0

… 100.0 %

0.1%

± 2.5% V and A (± 5%

%r)

 

 

 

 

Watt)

 

 

 

 

Hz

0 … 3500 Hz

1 Hz

± 1Hz

 

 

 

 

 

 

Phase angle

 

 

 

 

± n × 1º (8)

Fluke 435

-360º ... +0º

Fluke 434

-360º ... +0º

± n × 1.5º (8)

23-6