Sensors - Check status of the sensors

Power Supply Redundancy Configuration

IThis functionality is not available with all servers.

The Power Supply Redundancy Configuration group allows you to set the redundancy mode for the managed server. It depends on the servers capabilities which options are actually available.

PSU Redundancy 1 + 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 2 PSUs in total.

PSU Redundancy 2+ 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 3 PSUs in total.

PSU Redundancy 3+ 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 4 PSUs in total.

AC Redundancy 2 + 2 (2 AC sources)

2 of the 4 PSUs are each connected to a separate AC source. This ensures that the system can continue operation even if a power line or a single PSU fails.

AC Redundancy 1 + 1 (2 AC sources)

Each PSU (of 2 PSUs in total) is connected to a separate AC source. This ensures that the system can continue operation even if a power line or a single PSU fails.