Power Management

System Identification LED

As long as the System Identification LED is on, the iRMC S3 will not enable 0 Watt mode.

Advanced Video Redirection (AVR)

If an AVR session is currently active, the iRMC S3 will not enable

0 Watt mode. Once all AVR sessions have been finished (i.e, no AVR is active), the iRMC S3 will enable 0 Watt mode.

Remote Storage Server (RSS), Telnet/SSH Sessions

If an RSS session or an SSH/Telnet session is currently active, the iRMC S3 will not enable 0 Watt mode. This prevents the remote interface connections to the iRMC S3 from being lost.

AC power fail

If an AC fail occurs and the PSU (Power Supply Unit) is in the 0 Watt mode or in the scheduled mode, the PSU will return to system standby. Depending on the power restore policy settings (see page 192), the iRMC S3 determines whether the server is to be powered on. If the power restore policy is set to Always power off, an AC fail will never result in 0 Watt mode. 0 Watt mode may be reached after the next system power on.

Scheduled

Enables 0 Watt mode and also displays the 0 Watt Technology Administration Window. The 0 Watt Technology Administration Window allows you to specify a time interval at which the PSU is awoken from 0 Watt mode and thus both remote management and Wake-on-LAN (WOL) can be used.

Figure 108: Power Options page, 0 Watt Technology Administration window

Start Time

Defines the beginning (hh:mm) of the time interval.

196

iRMC S2/S3

Page 196
Image 196