IPMI OEM Commands supported by the iRMC S2/S3

01 20 - Set Next Power On Time

This command switches on a system at the given time independent of the stored On/Off times in the Configuration Space.

IThe command takes effect only once.

You cancel a “Power On” time previously set with a 01 20 command by specifying the “Power On” time “0” in a subsequent 01 20 command.

Request Data

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

-

01

Cmd : Command Group Communication

 

 

 

 

1:3

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

4

20

Command Specifier

 

 

 

 

 

5

00

Object ID

 

 

 

 

 

6:7

00 00

Value ID

 

 

 

 

 

8

04

Data Length

 

 

 

 

9:12

Time (LSB first) (see below)

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

-

01

 

 

 

 

 

1

Completion Code

 

 

 

 

2:4

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

Time (LSB first)

Time (UNIX-specific format) when the system switches on again. Time is NOT stored in non-volatile memory. Resolution is 1 minute. After the system has switched on, Time is set to 0 internally.

If Time == 0, the system is not switched on.