IPMI OEM Commands supported by the iRMC S2/S3

12.1.2.2 SCCI-compliant Power On/Off commands

01 15 - Get Power On Source

This command returns the reason for the most recent Power On. The possible reasons are listed below.

Request Data

 

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

 

 

 

 

-

01

Cmd : Command Group Communication

 

 

 

 

 

 

 

 

1:3

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

 

 

 

4

15

Command Specifier

 

 

 

 

 

 

Response Data

 

-

BC

 

 

 

 

 

 

 

 

 

 

-

01

 

 

 

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

 

 

2:4

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

 

 

 

3

01

Data Length

 

 

 

 

 

 

 

 

4

Power on Source: Cause of last power on

 

 

 

 

 

 

 

 

 

 

Power on

 

Description

 

 

Source

 

 

 

 

 

 

 

 

 

0x00

 

Software or command

 

 

 

 

0x01

 

Power switch (on the front panel or keyboard)

 

 

 

0x02

 

Automatic restart after power failure

 

 

 

0x03

 

Clock or timer (hardware RTC or software timer)

 

 

 

0x04

 

Automatic restart after fan failure shutdown

 

 

 

0x05

 

Automatic restart after critical temperature shutdown

 

 

 

0x08

 

Reboot after watchdog timeout

 

 

 

0x09

 

Remote on (modem RI line, SCSI termination power, LAN, chip card

 

 

reader...)

 

 

 

 

 

0x0C

 

Reboot after a CPU error

 

 

 

0x15

 

Reboot by hardware reset

 

 

 

0x16

 

Reboot after warm start

 

 

 

0x1A

 

Powered on by a PCI Bus Power Management Event

 

 

 

0x1D

 

Powered on by remote control via remote manager

 

 

 

0x1E

 

Reboot/reset by remote control via remote manager

 

 

 

 

 

 

388

iRMC S2/S3

Page 388
Image 388
Fujitsu IRMC S2/S3 manual 388, Power on Description Source