388 iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3

12.1.2.2 SCCI-compliant Power On/Off commands

01 15 - Get Power On Source

This command returns the reason for the most recent Power On. The possible

reasons are listed below.

Request Data - B8 NetFnlLUN: OEM/Group
-01 Cmd : Command Group Communication
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
415 Command Specifier
Response Data - BC
-01
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first
301 Data Length
4 Power on Source: Cause of last power on
Power on
Source
Description
0x00 Software or command
0x01 Power switch (on the front panel or keyboard)
0x02 Automatic restart after power failure
0x03 Clock or timer (hardware RTC or software timer)
0x04 Automatic restart after fan failure shutdown
0x05 Automatic restart after critical temperature shutdown
0x08 Reboot after watchdog timeout
0x09 Remote on (modem RI line, SCSI termination power, LAN, chip card
reader...)
0x0C Reboot after a CPU error
0x15 Reboot by hardware reset
0x16 Reboot after warm start
0x1A Powered on by a PCI Bus Power Management Event
0x1D Powered on by remote control via remote manager
0x1E Reboot/reset by remote control via remote manager