Configuring the iRMC S2/S3 via SCCI and scripted configuration

Parameters of SCCI provider-specific commands

The following SCCI-provider-specific commands are available:

Operation Code (OC)

Hex value or string specifying the command / operation code.

IThe iRMC S2/S3 only supports a limited set of SCCI commands. For a list of supported commands see table "SCCI commands supported by the iRMC S2/S3" on page 420

Operation Code Extension (OE)

Hex value for extended operation code. Default: OE=0

For ConfigSpace Read-/Write operations, this value defines the ConfigSpace ID.

Object Index (OI)

Hex value selecting an instance of an object. Default:OI=0"

Operation Code Type (Type)

For configuration settings, the values GET (read operation) and SET (write operation) are supported. Default: Type=GET

ISET operations require data. For specifying the appropriate data type, use the Data (DATA) parameter described below.

Cabinet Identifier (CA)

Allows you to select an extension cabinet and use its cabinet ID number.

IDo not use this parameter to request for the system cabinet!

Data (DATA)

If a SET parameter (write operation) is specified: Data type (Type parameter), and, in some cases, data length (LEN parameter) are required.

Currently, the following data types are supported:

xsd::integer

Integer value

Example

<DATA Type="xsd::integer">1234</DATA>