IPMI OEM Commands supported by the iRMC S2/S3

12.1.2.4 SCCI-compliant signaling command

10 02 - Write to System Display

This command is used to write characters to the LocalView display (if connected).

Request Data

 

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

 

 

-

10

Cmd : Command Group Fan Test

 

 

 

 

 

 

 

1:3

80

28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

 

4

02

Command Specifier

 

 

 

 

 

 

5

Object Index: : Line on Display to write on.

 

 

 

 

 

 

6:7

Value ID (not used)

 

 

 

 

 

 

8

Length Number of characters to write, incremented by

 

 

 

one. (The string need not be null-terminated; characters

 

 

 

exceeding the length of a display line are truncated.)

 

 

 

 

 

 

9

Attribute:

 

 

 

0

= Write String left aligned.

 

 

 

1 = Write String centered.

 

 

 

 

 

 

10:10+n

Characters to write to the display; string need not be null-

 

 

 

terminated.

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

-

10

 

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

 

2:4

80

28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

iRMC S2/S3

395

Page 395
Image 395
Fujitsu IRMC S2/S3 manual 395, Attribute