Server Management Information - Configuring the server settings

Power Cycle Delay (0 - 15)

Time (in seconds) between powering down and powering up during a power cycle.

ÊClick Apply to save your settings.

The configured settings are saved and the actions which have been configured are performed in the appropriate circumstances.

Watchdog Settings - Configure software watchdog and boot watchdog

The Watchdog Settings group allows you configure the software watchdog and the boot watchdog.

IThe settings made on the ASR&R Options group become active the next time the managed server is started.

Figure 134: Server Management Information page, Watchdog Options

The software watchdog

monitors the activities of system using the ServerView agents. The software watchdog is activated when the ServerView agents and the operating system have been completely initialized.

The ServerView agents contact the iRMC S2/S3 at defined intervals. If no more messages are received from a ServerView agent, it is assumed that the system is no longer functioning correctly.

You can specify an action to be performed if this happens.

The boot watchdog monitors the phase between startup of the system and the time at which the ServerView agents become available.

If the ServerView agents do not establish a connection to the iRMC S2/S3 of the server within a specified time, it is assumed that the boot process has not been successful.

You can specify an action to be performed if this happens.

iRMC S2/S3

235

Page 235
Image 235
Fujitsu IRMC S2/S3 manual 235, Server Management Information page, Watchdog Options