410 iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
F5 DF - Reset Nonvolatile Cfg Variables to Default
This command forces all non-volatile IPMI settings to be set to default values.
F5 E0 - Reset ConfigSpace variables to default
This command forces all Configuration Space variables to be set to default
values.
Request Data - B8 NetFnlLUN: OEM/Group
-F5 Cmd : Command Group BMC
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4DF Command Specifier
5:8 43 4C 52 AA = ’CLR’0xaa: Security Code
Response Data - BC
-F5
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first
Request Data - B8 NetFnlLUN: OEM/Group
-F5 Cmd : Command Group BMC
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4E0 Command Specifier
5:8 43 4C 52 AA = ’CLR’0xaa: Security Code
Response Data - BC
-F5
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first