IPMI OEM Commands supported by the iRMC S2/S3

F5 DF - Reset Nonvolatile Cfg Variables to Default

This command forces all non-volatile IPMI settings to be set to default values.

Request Data

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

-

F5

Cmd : Command Group BMC

 

 

 

 

 

 

1:3

80

28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

4

DF

Command Specifier

 

 

 

 

 

5:8

43

4C 52 AA = ’CLR’0xaa: Security Code

 

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

 

-

F5

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

2:4

80

28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

F5 E0 - Reset ConfigSpace variables to default

This command forces all Configuration Space variables to be set to default values.

Request Data

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

-

F5

Cmd : Command Group BMC

 

 

 

 

 

 

1:3

80

28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

4

E0

Command Specifier

 

 

 

 

 

5:8

43

4C 52 AA = ’CLR’0xaa: Security Code

 

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

 

-

F5

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

2:4

80

28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 