Updating firmware images

Proceed as follows:

IAn online update using a USB memory stick is described below (see section "Setting up the USB memory stick" on page 357).

ÊConnect the USB memory stick to the managed server.

ÊIn the Windows command line or the Linux Command Line Interface (CLI) switch to the drive corresponding to the USB memory stick.

ÊSet the firmware selector to the value 4 by calling the flash tool with the parameter /s 4.

E.g., in the Windows command line you enter:

WinFLIRMCS2 /s 4

ÊStart the update of the firmware and the SDR data by calling the flash tool with the corresponding update files.

E.g., in the Windows command line you enter:

WinFLIRMCS2 dcod<firmware-version>.bin <nnnnnnn>.sdr /i

During the firmware update, the console informs you about the progress of the update operation. If an error occurs, the update operation is aborted and a corresponding return code is reported (see page 370).

ÊRestart the managed server. This automatically activates the firmware image with the updated firmware.