iRMC S2/S3 firmware (overview)

10.1iRMC S2/S3 firmware (overview)

The iRMC S2/S3 uses two different firmware images. The two firmware images are stored on a 16-MB EEPROM (Electrically Erasable Programmable Read- Only Memory):

Firmware image 1 (low FW image)

Firmware image 2 (high FW image)

The firmware of the iRMC S2/S3 is not executed in the EEPROM, but is instead loaded into SRAM memory on startup and executed there. This means that it is possible to update both active and inactive firmware images online, i.e. with the server operating system (Windows or Linux) running.

IIf an error occurs while loading the firmware from one of the images, the firmware is automatically loaded from the other image.

IInformation on the iRMC S2/S3 firmware and EEPROM can be found

in the iRMC S2/S3 web interface, page iRMC S2/S3 Information (see page 164) or

using the flash tool (see page 368).

Active and passive firmware image

One of the two firmware images is active (running) at any given time, while the other is inactive. The firmware image that is active depends on the so-called firmware selector (see page 356).

354

iRMC S2/S3

Page 354
Image 354
Fujitsu manual IRMC S2/S3 firmware overview, Active and passive firmware image