Configuring the iRMC S2/S3 via SCCI and scripted configuration

12.2.2 Scripted configuration of the iRMC S2/S3

This section describes provides information on the following topics:

SCCI commands supported by the iRMC S2/S3.

Using various script languages for scripted configuration of the iRMC S2/S3.

Generating encrypted passwords with the iRMC_PWD.exe program.

12.2.2.1List of SCCI commands supported by the iRMC S2/S3

The SCCI commands supported by the iRMC S2/S3 are shown in table 19:

SCCI OpCode

SCCI Command String

Description

 

 

 

0xE002

ConfigSpace

ConfigSpace Write

 

 

 

0x0111

PowerOnCabinet

Power On the Server

 

 

 

0x0112

PowerOffCabinet

Power Off the Server

 

 

 

0x0113

PowerOffOnCabinet

Power Cycle the Server

 

 

 

0x0204

ResetServer

Hard Reset the Server

 

 

 

0x020C

RaiseNMI

Pulse the NMI (Non Maskable Interrupt)

 

 

 

0x0205

RequestShutdownAndOff

Graceful Shutdown, requires running

 

Agent

 

 

 

 

 

0x0206

RequestShutdownAndReset

Graceful Reboot, requires running Agent

 

 

 

0x0209

ShutdownRequestCancelled

Cancel a Shutdown Request

 

 

 

0x0203

ResetFirmware

Perform a BMC Reset

 

 

 

0x0250

ConnectRemoteStorageServer

Connect or Disconnect a standalone

 

Remote Storage Server

 

 

 

 

 

Table 19: SCCI commands supported by the iRMC S2/S3