iRMC S2/S3 193
Power Management
Power On/Off Time - Specify power on/off times for the server
The input fields of the Power On/Off Time group allow you to specify the times at
which the server is powered up/down for the individual days of the week or for
specified times during the day.
ISpecifications in the Everyday field take priority!
The Trap fields also allow you to configure whether the iRMC S2/S3 sends an
SNMP trap to the management console before a planned power-on / power-off
of the managed server and, if so, how many minutes before the event this
should be done. No traps are sent if you specify the value “0”.
Figure 106: Power Options page, Power On/Off Time