408 iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
F5 B0 - Set Identify LED
This command allows you to switch the Identify LED (blue) of the server on and
off. In addition, you can set and read the GPIOs that are directly connected to
the Identify LED.
IYou can also switch the Identify LED on and off using the Identify switch
on the server.
F5 B1 - Get Identify LED
This command returns information on the status of the Identify LED (blue) of the
server.
Request Data - B8 NetFnlLUN: OEM/Group
-F5 Cmd : Command Group BMC
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4B0 Command Specifier
5Identify LED:
0: Identify LED off
1: Identify LED on
Response Data - BC
-F5
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first
Request Data - B8 NetFnlLUN: OEM/Group
-F5 Cmd : Command Group BMC
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4B1 Command Specifier
Response Data - BC
-F5
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first
5 State of Identify LED (only bit 0 is relevant)