IPMI OEM Commands supported by the iRMC S2/S3

F5 B0 - Set Identify LED

This command allows you to switch the Identify LED (blue) of the server on and off. In addition, you can set and read the GPIOs that are directly connected to the Identify LED.

IYou can also switch the Identify LED on and off using the Identify switch on the server.

Request Data

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

-

F5

Cmd : Command Group BMC

 

 

 

 

1:3

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

4

B0

Command Specifier

 

 

 

 

5

Identify LED:

 

 

0: Identify LED off

 

 

1: Identify LED on

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

-

F5

 

 

 

 

 

1

Completion Code

 

 

 

 

2:4

80 28 00 IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

F5 B1 - Get Identify LED

This command returns information on the status of the Identify LED (blue) of the server.

Request Data

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

-

F5

Cmd : Command Group BMC

 

 

 

 

 

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

4

B1

Command Specifier

 

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

 

-

F5

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

5

State of Identify LED (only bit 0 is relevant)

 

 

 

 

 