Updating firmware images

10.3.4 Update using the operating system flash tools.

IAn online update using the operating system flash tools is only
performed as a recovery flash, i.e. no version check is performed.
IPrerequisite:
The flash tools and the files for the firmware update must be present in
the file system of the managed server.
You use one of the following flash tools, depending on the operating system you
are running:
You call the flash tools in the Windows command line (flirmcs2, win32flirmcs2,
win64flirmcs2, winflirmcs2) or at the Linux CLI (linflirmcs2).
The syntax and operands for the flash tools are described in section "Flash
tools" on page 368.
DOS: flirmcs2
Windows: winflirmcs2
Prerequisite:
The ServerView agents for the used Windows operation
system (32/64 bit) must be running on the managed server.
Windows (32 bit): win32flirmcs2 (No agents required.)
Windows (64 bit): win64flirmcs2 (No agents required.)