IPMI OEM Commands supported by the iRMC S2/S3

12.1.2.3 SCCI-compliant communication commands

IDie SCCI-compliant communication commands require that the Agent Service is running under the OS. To execute the commands, the iRMC S2/S3 communicates with Agent which finally performs the action.

02 05 - System OS Shutdown Request

This command initiates shutdown of the server’s operating system.

Request Data

 

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

 

 

-

02

Cmd : Command Group Communication

 

 

 

 

 

 

 

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

 

4

05

Command Specifier

 

 

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

 

 

 

-

02

 

 

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

 

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

02 06 - System OS Shutdown Request and Reset

This command initiates the shutdown of the server’s operating system and subsequently restarts the system.

Request Data

 

-

B8

NetFnlLUN: OEM/Group

 

 

 

 

 

 

 

-

02

Cmd : Command Group Communication

 

 

 

 

 

 

 

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 

 

4

06

Command Specifier

 

 

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

 

 

 

 

-

02

 

 

 

 

 

 

 

 

1

Completion Code

 

 

 

 

 

 

 

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

 

 

 

 

 

 