IPMI OEM Commands supported by the iRMC S2/S3

01 1C - Set Power Off Inhibit

This command sets the Power Off Inhibit flag, which temporarily suppresses any unfounded attempt to power down the server.

If the Power Off Inhibit flag is set, the firmware saves the cause of any attempt to perform a “Power Off”, “Power Cycle” or restart of the server, but does not perform the action. The cause of the most recent attempt to perform a “Power Off”, “Power Cycle” or restart of the server is always saved at any given time. The stored action is only performed when the Power Off Inhibit flag is reset.

The Power Off Inhibit flag is automatically reset after a power failure or when the reset button is pressed.

The effect of the Power Off Inhibit flag is the same as that of the Dump flag used when creating a main memory dump. In this case, the initiator must set the flag before making the dump and reset it when the dump is complete.

Request Data

-

B8

NetFnLUN: OEM/Group

 

 

 

 

 

-

01

Cmd : Command Group Communication

 

 

 

 

1:3

80 28 00 IANA-Enterprise-Number FTS, LS Byte first

 

 

 

 

 

4

1C

Command Specifier

 

 

 

 

 

5

00

Object ID

 

 

 

 

6:7

00 00 Value ID

 

 

 

 

 

8

01

Data Length

 

 

 

 

9

Power Off Inhibit Flag: 0 no Inhibit, 1 Inhibit

 

 

 

 

Response Data

-

BC

 

 

 

 

 

 

-

01

 

 

 

 

 

1

Completion Code

 

 

 

 

2:4

80 28 00 IANA-Enterprise-Number FTS, LS Byte first

 

 

 

 

390

iRMC S2/S3

Page 390
Image 390