390 iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
01 1C - Set Power Off Inhibit
This command sets the Power Off Inhibit flag, which temporarily suppresses any
unfounded attempt to power down the server.
If the Power Off Inhibit flag is set, the firmware saves the cause of any attempt to
perform a “Power Off”, “Power Cycle” or restart of the server, but does not
perform the action. The cause of the most recent attempt to perform a “Power
Off”, “Power Cycle” or restart of the server is always saved at any given time.
The stored action is only performed when the Power Off Inhibit flag is reset.
The Power Off Inhibit flag is automatically reset after a power failure or when the
reset button is pressed.
The effect of the Power Off Inhibit flag is the same as that of the Dump flag used
when creating a main memory dump. In this case, the initiator must set the flag
before making the dump and reset it when the dump is complete.
Request Data - B8 NetFn|LUN: OEM/Group
-01 Cmd : Command Group Communication
1:3 80 28 00 IANA-Enterprise-Number FTS, LS Byte first
41C Command Specifier
500 Object ID
6:7 00 00 Value ID
801 Data Length
9 Power Off Inhibit Flag: 0 no Inhibit, 1 Inhibit
Response Data - BC
-01
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS Byte first