Using AVR

5.2.3Local Monitor Off" function

The Local Monitor Off function of the iRMC S2/S3 allows you to power down the local monitor of the managed server for the duration of your AVR session. In this way, you ensure that the inputs you make and the actions you perform on the local monitor on the server using AVR cannot be seen. The identification LED flashes to indicate "Local Monitor Off" mode on the server.

You configure the “Local Monitor Off” function on the Advanced Video Redirection page of the iRMC S2/S3 web interface (see page 302). After you have configured the system appropriately, you can switch the local monitor of the server on and off from the remote workstation as follows:

In Full Control mode in an AVR session using the Extras menu

directly on the Advanced Video Redirection page with administrator or OEM permissions

You can also configure that the local monitor is always switched off automatically whenever a new AVR session is started.

The current status of the local monitor is shown in the AVR window in blue letters to the top right of the integrated special keys:

The local monitor is always switched on and cannot be switched off, as the Enable Local Monitor Off option (see page 307) is deactivated.

Local Monitor On

The local monitor is on, but can be switched off.

Local Monitor Off

The local monitor is off, but can be switched on.

Local Monitor always off

The local monitor is always switched off and cannot be switched on because a high-resolution graphics mode has been set on the managed server (see table 3 on page 86).

90

iRMC S2/S3

Page 90
Image 90
Fujitsu IRMC S2/S3 manual Local Monitor Off function, Local monitor is on, but can be switched off