iRMC S2/S3 - Information, firmware and certificates

Update file

File in which the firmware image is stored.

IThe files listed below each allow you to update one component of the iRMC S2/S3 firmware every time TFTP is started (runtime firmware and SDR record).

The file rt_sdr_<D-number>_4_08g_00.binis also available for some PRIMERGY servers / blade servers. This allows you to update all the components of the iRMC S2/S3 firmware in a single operation using a TFTP server.

dcod<FW-Version>.bin

Updates the runtime firmware.

<SDR-Version>.SDR

Updates the SDR record.

Flash Selector

Specify what iRMC firmware is to be updated.

You have the following options:

Auto - inactive firmware

The inactive firmware is automatically selected.

Low Firmware Image

The low firmware image (firmware image 1) is selected.

High Firmware Image

The high firmware image (firmware image 2) is selected.

ÊClick Apply to activate your settings.

ÊClick TFTP Test to test the connection to the TFTP server.

ÊClick TFTP Start to download the file containing the firmware image from the TFTP server and to start updating the iRMC S2/S3 firmware.