62 iRMC S2/S3
Configuring and using the serial interface of the iRMC S2/S3
Flow Control
None
Exiting the UEFI setup utility
ÊSave your settings and exit the UEFI setup utility.
ÊContinue with section "Testing the LAN interface" on page 47.

3.3.3 Using the Remote Manager (Serial) interface

If you connect a computer over a null modem cable and start a terminal program
(VT100+) on this computer, you can access the Remote Manager (Serial)
terminal program. The Remote Manager (Serial) interface is identical to the
Remote Manager interface (see chapter "iRMC S2/S3 via Telnet/SSH (Remote
Manager)" on page 321).
Prerequisites
On the managed server:
The Serial Multiplexer BIOS setting must be configured on the iRMC (see
section "Configuring the serial interface of the iRMC S2" on page 58).
Terminal program (VT100+):
Configure the following port settings for the terminal program:
Bits per second
Set the value to 9600.
Data bits
Set the value to 8.
Parity
Set the value to None.
Stop bits
Set the value to 1.
Flow Control
Set the value to None.