Configuring and using the serial interface of the iRMC S2/S3

Flow Control

None

Exiting the UEFI setup utility

ÊSave your settings and exit the UEFI setup utility.

ÊContinue with section "Testing the LAN interface" on page 47.

3.3.3Using the Remote Manager (Serial) interface

If you connect a computer over a null modem cable and start a terminal program (VT100+) on this computer, you can access the Remote Manager (Serial) terminal program. The Remote Manager (Serial) interface is identical to the Remote Manager interface (see chapter "iRMC S2/S3 via Telnet/SSH (Remote Manager)" on page 321).

Prerequisites

On the managed server:

The Serial Multiplexer BIOS setting must be configured on the iRMC (see section "Configuring the serial interface of the iRMC S2" on page 58).

Terminal program (VT100+):

Configure the following port settings for the terminal program:

Bits per second

Set the value to 9600.

Data bits

Set the value to 8.

Parity

Set the value to None.

Stop bits

Set the value to 1.

Flow Control

Set the value to None.

62

iRMC S2/S3

Page 62
Image 62
Fujitsu IRMC S2/S3 manual Using the Remote Manager Serial interface, Prerequisites, On the managed server, Set the value to