Address

Line

Pt

DNP

Description

Range

Units

Type

R/W

 

 

 

Obj

 

 

 

 

 

46733-46734

 

 

 

Relay 14 Combination Tree Input Line 1, Point 1

 

 

 

R

46735-46736

 

 

 

Relay 14 Combination Tree Input Line 2, Point 2

 

 

 

R

46737-46738

 

 

 

Relay 14 Combination Tree Input Line 3, Point 3

 

 

 

R

46739-46740

 

 

 

Relay 14 Combination Tree Input Line 4, Point 4

 

 

 

R

46741-46742

 

 

 

Relay 14 Combination Tree Input Line 5, Point 5

 

 

 

R

46743-46744

 

 

 

Relay 14 Combination Tree Input Line 6, Point 6

 

 

 

R

46745-46746

 

 

 

Relay 14 Combination Tree Input Line 7, Point 7

 

 

 

R

46747-46748

 

 

 

Relay 14 Combination Tree Input Line 8, Point 8

 

 

 

R

46749

 

 

 

Relay 14 Combination Logic (Combination A/ Combination B)

 

 

 

R

46750

 

 

 

Relay 14 Combination Logic (Combination C/ Combination D)

 

 

 

R

46751

 

 

 

Relay 14 Combination Logic (Combination E/ Combination F)

 

 

 

R

46752

 

 

 

Relay 14 Combination Logic (Combination G/ Reserved)

 

 

 

R

46753

 

 

 

Relay 14 Set Delay/ Reset Delay

 

 

 

R

46754-46756

 

 

 

Reserved

 

 

 

R

46757-46758

 

 

 

Relay 15 Combination Tree Input Line 1, Point 1

 

 

 

R

46759-46760

 

 

 

Relay 15 Combination Tree Input Line 2, Point 2

 

 

 

R

46761-46762

 

 

 

Relay 15 Combination Tree Input Line 3, Point 3

 

 

 

R

46763-46764

 

 

 

Relay 15 Combination Tree Input Line 4, Point 4

 

 

 

R

46765-46766

 

 

 

Relay 15 Combination Tree Input Line 5, Point 5

 

 

 

R

46767-46768

 

 

 

Relay 15 Combination Tree Input Line 6, Point 6

 

 

 

R

46769-46770

 

 

 

Relay 15 Combination Tree Input Line 7, Point 7

 

 

 

R

46771-46772

 

 

 

Relay 15 Combination Tree Input Line 8, Point 8

 

 

 

R

46773

 

 

 

Relay 15 Combination Logic (Combination A/ Combination B)

 

 

 

R

46774

 

 

 

Relay 15 Combination Logic (Combination C/ Combination D)

 

 

 

R

46775

 

 

 

Relay 15 Combination Logic (Combination E/ Combination F)

 

 

 

R

46776

 

 

 

Relay 15 Combination Logic (Combination G/ Reserved)

 

 

 

R

46777

 

 

 

Relay 15 Set Delay/ Reset Delay

 

 

 

R

46778-46780

 

 

 

Reserved

 

 

 

R

46781-46782

 

 

 

Relay 16 Combination Tree Input Line 1, Point 1

 

 

 

R

46783-46784

 

 

 

Relay 16 Combination Tree Input Line 2, Point 2

 

 

 

R

46785-46786

 

 

 

Relay 16 Combination Tree Input Line 3, Point 3

 

 

 

R

46787-46788

 

 

 

Relay 16 Combination Tree Input Line 4, Point 4

 

 

 

R

46789-46790

 

 

 

Relay 16 Combination Tree Input Line 5, Point 5

 

 

 

R

2- 166