Required Information

EMC Storage source system:

IP address of the EMC SMI-S Provider that is managing the source EMC Storage system from which the volumes are being migrated.

If the SMI-S server is managing more than one source EMC Storage system, and you want to identify only one of them, you need to know the WWN of the source storage system.

User name and password for EMC SMI-S Provider.

Port to access EMC SMI-S Provider.

Secure port default 5989.

Non-secure port default 5988.

Destination HP 3PAR StoreServ Storage system:

IP address of the destination HP 3PAR StoreServ Storage system.

User name and password for the HP 3PAR management application with Super user permission.

Identifying the Source Storage System

To identify the source storage system, follow these steps:

1.From the HP 3PAR Online Import Utility, execute the addsource command.

NOTE: Use your local host user name and password credentials to log into the HP 3PAR Online Import Utility.

Example 1 addsource command

>addsource -type VNX -mgmtip 10.10.10.10 -user admin -password adminpw —uid xxxxxxxxxxxxxxxx

>SUCCESS: Added source storage system

2.Execute the showsource command to verify the source storage system information.

Example 2 showsource command

>showsource –type VNX

 

 

 

 

NAME

TYPE UNIQUE_ID

FIRMWARE

MANAGEMENT_SERVER OPERATIONAL_STATE

CLARiiON+APM00125345014

VNX 50067890BEE0177F

05.32.000.5.201

10.10.10.10

Good

 

 

 

 

 

36 Preparing for Data Migration