1.From the HP 3PAR Online Import Utility, execute the createmigration command.

Example 32 createmigration command

>createmigration -sourceuid 50067890C6E059EE -srchost "HPDL585-01" -destcpg "FC_r5" -destprov thin -migtype

MDM

>SUCCESS: Migration job submitted successfully. Please check status/details using showmigration command. Migration id: 1395864499741

NOTE: Be aware, the createmigration command may take several minutes to complete.

TIP: Make a note of the Migration ID as it will be used in commands to track migration progress.

2.Execute the showmigration command to verify that the data migration task preparation has completed successfully. This may take some time. On the successful creation of the task the STATUS column will indicate preparationcomplete(100%).

Example 33 showmigration command

>showmigration -migrationid 1395864499741

 

 

 

MIGRATION_ID

TYPE

SOURCE_NAME

DESTINATION_NAME

START_TIME

END_TIME

STATUS(PROGRESS)(MESSAGE)

 

 

 

1395864499741

MDM

CLARiiON+APM00123452867

3par_7200_DCA_01

Wed Mar 26 13:08:19 PDT 2014

-NA-

preparationcomplete(100%)(-NA-)

 

 

 

3.Execute the showmigrationdetails command to verify the volumes being migrated. In the preparation stage, PROGRESS for each volume will be 0% and the TASK_ID will be unknown.

Example 34 showmigrationdetails command

>showmigrationdetails -migrationid 1395864499741

SOURCE_VOLUME

DESTINATION_VOLUME

TASK_ID

PROGRESS

OIU_Test_Lun_01

OIU_Test_Lun_01

unknown

0%

Updating Host Multipath Software and Unzoning from Source EMC Storage System

CAUTION: EMC PowerPath must not be installed during the migration process. Native device-mapper-multipath must be managing the paths.

Stop all applications before removing EMC PowerPath. For cluster configurations, also stop the cluster services and the cluster. Applications should be restarted after migration has started.

Perform the following steps on the Linux host:

1.Remove EMC PowerPath Multipath software from the host by following these steps:

a.Close all applications on the host.

b.For a cluster, stop the cluster services, and then stop the cluster.

Updating Host Multipath Software and Unzoning from Source EMC Storage System 57

Page 57
Image 57
HP Online Import Software manual Example 32 createmigration command, Example 33 showmigration command