Table 32 Mapping Path Statuses and Required Actions (continued)

Status

Description

External device setting changed

The setting of the external storage

 

system has been changed. For

 

example, the path definition was

 

deleted, or the external storage system

 

itself was replaced by another device.

LDEV size reduced

The setting of the volume capacity of

 

the external storage system has been

 

changed (the volume capacity was

 

reduced).

Not ready

The reply of the external storage

 

system was NOTREADY. The drive of

 

the external storage system is spinning

 

up, or the device of the external

 

storage system is being formatted.

Illegal request

The reply of the external storage

 

system was ILLEGALREQUEST. The

 

command cannot be executed to the

 

device of the external storage system.

 

The data protection may be set on the

 

device of the external storage system.

Command aborted

The reply of the external storage

 

system was ABORTEDCOMMAND.

 

An error may have occurred on the

 

external storage system side.

Action

The port of the external storage system is recognized. See the documents for your external storage system, and check if the operation that changes the setting information about the mapped device has not been performed.

Check the volume capacity of the volume of the external storage system. Execute the Delete Volume operation, and then retry the Add Volume operation.

The path cannot be used to access the external storage system. Check the status of the external storage system. If you cannot restore the path, call HP technical support.

The port of the external storage system is recognized. Check the setting of the external storage system. If you cannot restore the path, call HP technical support.

The port of the external storage system is recognized. Check the setting of the external storage system and the condition of the connection (for example, cables, switches) to the external storage system. If you cannot restore the path, call HP technical support.

Busy

The external storage system is in the

 

BUSY status.

The port of the external storage system is recognized. Check the setting of the external storage system and the load on the external storage system (for example, check if the configuration gives too much load on the external storage system or not). If you cannot restore the path, call HP technical support.

LDEV reserved

The external storage system is in the

 

Reserve status. You are not allowed to

 

access the device of the external

 

storage system from the local storage

 

system.

Response error

The external storage system is in the

 

blocked status caused by the abnormal

 

reply (Response). You may not be able

 

to access the device of the external

 

storage system. Or data protection

 

may be set on the device of the

 

external storage system.

Remove the Reserve status on the device of the external storage system.

The port of the external storage system is recognized. Check the setting and status of the external storage system. If you cannot restore the path, call HP technical support.

Initiator port

The port attribute of the external

 

storage system has been changed to

 

the initiator port.

Set the port attribute of the external storage system to the target port. If you cannot restore the path, call HP technical support.