Fujitsu FibreCAT CX Series
System Option mode
When you connect a Fujitsu FibreCAT CX series as an external storage system, set system option mode 725 of the local storage system. If system option mode 725 is not set, the external storage system might be blocked when performing maintenance, including rebooting the controller of the external storage system by the firmware update and so on. For instructions about setting system option mode 725, contact
System Parameter for Connecting Fujitsu FibreCAT CX Series
When you connect a Fujitsu FibreCAT CX series as an external storage system, set the system parameters of the Fujitsu FibreCAT CX series according to the following table. For the system parameters that are not in the following table, refer to the documentation of the Fujitsu FibreCAT CX series and set the parameters appropriately for the connecting configuration.
Table 58 System Parameters for Connecting Fujitsu FibreCAT CX Series
Parameter | Parameter Setting |
Initiator Type | CLARiiON Open |
Failover Mode | 2 |
Notes on Connecting Fujitsu FibreCAT CX Series
Volumes created with the RAID0 level or Individual Disk Units (JBOD disks) of Fujitsu FibreCAT CX series are not supported.
SGI IS4600 Series
When connecting an SGI IS4600 series as an external storage system, set the system parameters of the SGI IS4600 series according to the following table. For system parameters that are not in the following table, refer to the documentation of the SGI IS4600 series and set the parameters appropriately for the connecting configuration.
Table 59 SGI IS4600 Series
Parameter | Parameter Setting |
host type | When alternate paths are connected to different clusters |
| on the SGI IS4600 series side: Linux |
Non-HP Storage Systems
Generally, when connecting a