When you use the Thunder 9500V storage system as an external storage system, the following versions are recommended. If you use a 9500V storage system whose version is earlier than the following versions, the information about the SATA drive may not be displayed correctly.

For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later.

For Thunder 9580V, Thunder 9585V: version 1658 or later.

Relationship between the Serial Number and Thunder 9500V Model

When the external storage system is Thunder 9500V storage system, you can identify the storage system model from the serial number displayed in the Serial Number column in the Volume Operation window.

Table 40 (page 140) describes the relationship between the serial number displayed in the Serial Number column and the storage system model.

Table 40 Relationship between the Serial Number and Thunder 9500V Model

Displayed Serial Number

Model

D600XXXX

9570V, 9520V

 

 

D60JXXXX

9530V

 

 

D60HXXXX

9580V, 9585V

 

 

NOTE: In serial numbers, X is an arbitrary number or character.

Relationship between the WWN of the Port and Controller

When the external storage system is Thunder 9500V storage system, you can identify the controller (controller 0 or controller 1) from the WWN of the port.

Table 41 (page 140) describes the relationship between WWN of port and controller.

Table 41 Relationship between the WWN of the Port and Controller (Thunder 9500V)

Model

 

Controller

WWN of the Port

 

 

 

 

9570V

 

Controller 0

XXXXXXXXXXXXXXX0

9530V

 

 

XXXXXXXXXXXXXXX1

9520V

 

 

 

 

Controller 1

XXXXXXXXXXXXXXX2

 

 

 

 

 

XXXXXXXXXXXXXXX3

 

 

 

 

9580V

 

Controller 0

XXXXXXXXXXXXXXX0

9585V

 

 

XXXXXXXXXXXXXXX1

 

 

 

XXXXXXXXXXXXXXX2

 

 

 

XXXXXXXXXXXXXXX3

 

 

 

 

 

 

Controller 1

XXXXXXXXXXXXXXX4

 

 

 

XXXXXXXXXXXXXXX5

 

 

 

XXXXXXXXXXXXXXX6

 

 

 

XXXXXXXXXXXXXXX7

 

 

 

 

NOTE:

In WWNs, X is an arbitrary number or character. The ports in the same apparatus have the identical value.

 

 

 

 

Path Status and Examples of the Recovery Procedure

This section describes errors that require recovery operation on the external storage system side when the path status is not normal. When the path status is not normal, see Table 42 (page 141)

140 Connecting External Storage Systems