7 Technical Reference

This section includes:

Connector pinouts

Information on jumpers

Connector Pinouts

This section describes certain I/O interface connectors of the xSeries 343 server.

Alarms

The alarms port interface is a standard DB15-pin connector (see Figure 34). This connector allows remote display of alarm conditions. Each alarm (Major, Minor, Critical and Power) is the output of a STDT relay contact. A common contact with normally open and normally closed connections is included. Power alarm has just a common and normally open contact outputs. The major and minor alarms contain external reset circuits. Table 12 gives the pinout of the alarms connector.

Note

Do not apply more than 60 Volts (maximum) to any pin or combination of pins on the Alarms connector.

 

 

1

8

 

 

9

15

 

 

Figure 34. 15-pin Alarms Connector

Table 12. Alarms Connector Pinout

 

 

Pin

Description

Pin

Description

1

Minor reset positive

9

Minor alarm normally closed

2

Minor reset negative

10

Minor alarm common

3

Major reset positive

11

Major alarm normally open

4

Major reset negative

12

Major alarm normally closed

5

Critical alarm normally open

13

Major alarm common

6

Critical alarm normally closed

14

Power alarm normally open

7

Critical alarm common

15

Power alarm common

8

Minor alarm normally open

 

 

91

Page 103
Image 103
IBM 343 manual Technical Reference, Connector Pinouts, Alarms, Pin Description