Environmental Specifications

The xSeries 343 system has been tested to the environmental specifications as indicated in Table 3. All testing has been performed per procedures defined in Bellcore GR-63-CORE NEBS Physical Protection, Bellcore GR-3580 NEBS Criteria Levels, Bellcore GR-1089-CORE EMC and Electrical Safety – Generic Criteria for Network Telecommunications Equipment, and the

Intel Environmental Standards Handbook.

Table 3. Environmental Specifications Summary

Environment

Specification

 

 

 

 

 

 

 

 

Temperature operating

5 ° C to 40

° C (41

° F to 104

° F)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature non-operating

-40 ° C to 70

° C (-104

° F to 158

° F)

 

 

 

 

 

 

 

 

 

 

 

Altitude

0 to 1,800 m (0 to 5,905 ft)

 

 

 

 

 

 

 

 

 

 

 

 

Humidity non-operating

95%, non-condensing at temperatures of 23

° C (73

° F) to 40

° C (104

° F)

 

 

 

 

 

Vibration operating

Swept sine survey at an acceleration amplitude of 0.1 g from 5 to 100 Hz

 

 

 

 

and back to 5 Hz at a rate of 0.1 octave/minute, 90 minutes per axis on all

 

 

 

three axes as per Bellcore GR-63-CORE standards.

 

 

 

 

 

 

 

 

Vibration non-operating

Swept sine survey at an acceleration amplitude of 0.5 g from 5 to 50 Hz at a

 

 

 

 

rate of 0.1 octaves/minute, and an acceleration amplitude of 3.0g from 50 to

 

 

 

 

500 Hz at a rate of 0.25 octaves/minute, on all three axes as per Bellcore

 

 

 

 

GR-63-CORE standard.

 

 

 

 

 

 

 

 

2.2 Grms, 10 minutes per axis on all three axes as per the Intel

 

 

 

 

Environmental Standards Handbook.

 

 

 

 

 

 

 

 

 

 

Shock operating

Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the

 

 

 

 

three axes as per the Intel Environmental Standards Handbook.

 

 

 

 

 

 

 

 

Shock non-operating

Trapezoidal, 25 G, 170-inch/sec delta V, three drops in each direction, on

 

 

 

 

each of the three axes as per Intel Environmental Standards Handbook.

 

 

 

 

 

 

 

 

Electrostatic discharge

Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to

 

 

 

(ESD)

8 kV contact discharge without physical damage as per Intel Environmental

 

 

 

 

Standards Handbook.

 

 

 

 

 

 

 

 

 

 

 

Acoustic

Sound pressure: < 55 dBA at ambient temperatures < 28

° C measured at

 

 

bystander positions in operating mode.

 

 

 

 

 

 

Sound power:

< 6.5 dBA at ambient temperatures < 28

° C in

 

 

 

operating mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis Description

9

Page 21
Image 21
IBM 343 manual Environmental Specifications Summary, Environment Specification